Kuba Kompakt NT

Temperature range: -25ºC/-20ºC

Refrigerating unit: External

Refrigerant/Cooling factor: R404A

Download PDF

LOW-TEMPERATURE SHOWCASE QUARTZ compact cube NT (L1 -18С Т -20С / -25С at +25С 60%)
Table 1 The main parameters of the display case KVARTs compact cube NT

Parameter nameUnit measurementsStandard size
125187250375
Useful volume temperature°C-25 – -20
Dimensions:
length excluding sidewallsmm1250187525003750
length with sides1330195525803830
width excluding sidewalls850850850850
width with sidewalls855855855855
height excluding sidewalls2210221022102210
height with sides2230223022302230
Layout depth:
main shelfmm620
additional shelves (6 shelves)500×6
Exposition area (main + 6 additional shelves)m24,496,749,0513,54
main shelf0,771,161,552,32
shelf 5000,620,931,251,89
Showcase volumem31,862,803,735,60
Useful volumem31,131,702,273,18
Consumed refrigerating power * 1 (at boiling point minus 35С)Watts700105014002100
Consumed electr. power in cooling mode, basic set / set GL * 2Watts420 / 395590 / 540755 / 6801050 / 950
Consumed electr. defrost power, basic setWatts2290354047457155
Electr. power consumed by lighting LED lampsWatts577695133
Rated power consumption per day * 3 basic set / set GLKilowatts per hour11,9 / 11,317,2 / 16,031,9 / 29,431,9 / 29,4
Power supply (nominal voltage – frequency – number of phases)Voltage380 – 50 – 3 /220 – 50 – 1
RefrigerantTypeR404A
Weight (without package)Kg280400520760
* 1 – in steady state at ambient air temperature 25С and relative humidity 60%.
* 2 – installed energy-saving fans (GreenLine equipment)
* 3 – four defrosts per day

Table 2 Technical information

Technical detailsQUARTZ compact cube NT
125187250375
TRV; Nozzle basic configurationTMVXBL-00208; 1,0 (Honeywell)TMVXBL-00208; 1,5 (Honeywell)TMVXBL-00208; 2,0 (Honeywell)TMVXBL-00208; 2,5 (Honeywell)
Fans:
basic configuration
1x33W
(4223.005)
2x33W
(4223.005)
3x33W
(4223.005)
4x33W
(4223.005)
equipment GL *1x7W (4223.010)2x7W (4223.010)3x7W (4223.010)4x7W (4223.010)
Lighting fluorescent lamps LED lamps3х28W (4135.015)
3х25W (4135.308)
4х28W (4135.015)
4х25W (4135.308)
5х28W (4135.015)
5х25W (4135.308)
7х28W (4135.015)
7х25W (4135.308)
PEN anti-condensation heating:
PEN heating door perimeter (RW1)RW1 – 33 W (4162.130)RW1 – 33 W (4162.130)RW1 – 33 W (4162.130)RW1 – 33 W (4162.130)
PEN heating racks (RW2)RW2 – 24 W (4162.137)RW2 – 57 W (4162.134)RW2 – 86 W (4162.135)RW2 – 137 W (4162.136)
PEN heating frame perimeter (RW3)RW3 – 231 W (4162.138)RW3 – 281 W (4162.131)RW3 – 332 W (4162.132)RW3 – 437 W (4162.133)
TEN defrost:
Heating elements for defrosting the evaporator (R1, R2, R3, R4)R1,R2 -380 W (4161.101)
R3,R4 -460 W (4161.051)
R1,R2 -650 W (4161.102)
R3,R4 – 690 W (4161.052)
R1,R2 -900 W (4161.103)
R3,R4 – 920 W (4161.053)
R1,R2 -1400 W (4161.104)
R3,R4 – 1380 W (4161.054)
Heating elements for defrosting b.m. (R5, R6)R5+R6** = 230 W (4161.055 + 4161.055)R5+R6** = 345 W (4161.056 + 4161.056)R5+R6** = 460 W (4161.057 + 4161.057)R5+R6** = 690 W (4161.058 + 4161.058 )
Defrost parameters: interval between defrosts / defrost time / end defrost temperature6 /30мин /10°С
Electronic controller: basic configuration optionDanfoss EKC-202D (4400.030)
Eliwell ID 985 LX (4311.002)
* GL – GreenLine equipment (energy-saving fans are installed).

** – series connected heating elements R5 + R6